Forced Convection Heat Rejection System for Mars Surface Applications

Authors

  • Nathan Colgan UW-Madison
  • Gregory Nellis UW-Madison
  • Mark Anderson UW-Madison

DOI:

https://doi.org/10.17307/wsc.v1i1.344

Keywords:

Mars, Heat exchanger, forced convection, heat rejection

Abstract

A forced convection heat exchanger for waste heat rejection to the Martian atmosphere is designed based on existing heat transfer and pressure drop correlations for low-Reynolds-number finned tube arrays. The design is optimized to determine the mass-optimal heat exchanger geometry for a range of candidate heat exchanger materials and power loads. For a 100 kW thermal load, the optimal heat exchanger mass is found to be 27.0 kg and a frontal area of 3.94 m2. This is 95% less mass and area than a comparable radiator and only requires 638 W of fan power (or 0.6% of the output power) to operate. Optimal geometries are also found for heat rejection loads of 1 kW to 250kW across a range of coolant and atmosphere temperatures, indicating wide applicability of this technology for Martian heat rejection applications such as cryofuel refrigeration or in-situ resource utilization (ISRU) plant cooling. An experimental facility has been designed and partially constructed to experimentally validate the predicted heat exchanger performance in a Mars-like environment. A subscale heat exchanger has been built based on the predicted mass-optimal geometry. Heat transfer and pressure drop performance data of this heat exchanger will be collected and will refine the modelling predictions.

Author Biographies

Nathan Colgan, UW-Madison

Graduate student in the Nuclear Engineering and Engineering Physics Department

Gregory Nellis, UW-Madison

Professor, Department of Mechanical Engineering

Mark Anderson, UW-Madison

Professor, Department of Mechanical Engineering

References

NASA-SP-2009-566, Human Exploration of Mars Design Reference Architecture (DRA) 5.0, National Aeronautics and Space Administration, Washington, D.C. (2009).

B. SONDELSKI, Mass Optimization of a Supercritical CO2 Brayton Cycle with a Direct Cooled Nuclear Reactor for Space Surface Power. Master’s Thesis, University of Wisconsin, Madison, (2019)

R.M. HABERLE, “Solar System/Sun, Atmospheres, Evolution of Atmospheres Planetary Atmospheres: Mars”, Encyclopedia of Atmospheric Sciences, (2015)

N. COLGAN, G. NELLIS, M. ANDERSON, “Mass Optimization of a Convective Heat Exchanger for Mars Surface Reactor Waste Heat Rejection”, Nuclear and Emerging Technologies for Space, Track 2: Nuclear Fission Power and Propulsion (pp. 20-24). American Nuclear Society, (2021)

R. FELDT. BlackBoxOptim.jl, (2019), Github Repository, https://github.com/robertfeldt/BlackBoxOptim.jl

Heat Exchanger Design Handbook (1983) Vol. 1, Hemisphere, New York, (1983)

G. MARTINEZ et al., “The Modern Near-Surface Martian Climate: A Review of In-situ Meteorological Data from Viking to Curiosity”, Space Sci Rev (2017) 212:295–338

M. ANYOJI, D. NUMATA, H. NAGAI, K. ASAI, “Effects of Mach Number and Specific Heat Ratio on Low-Reynolds-Number Airfoil Flows,” AIAA Journal, vol. 53, no. 6, pp. 1640–1654, Oct. 2014.

D. QUIN, R. GRIMES, “The Effect of Reynolds Number on Microaxial Flow Fan Performance”, Journal of Fluids Engineering, (2008)

J. NEUSTEIN, “Low Reynolds Number Experiments in an Axial Flow Turbomachine,” ASME J. Eng. Power, pp. 257–295. (1964)

M. VEISMAN, C. DOUGHERTY, J. RABINOVITCH, A. QUON, M. GHARIB, “Low‑Density Multi‑Fan Wind Tunnel Design and Testing for the Ingenuity Mars Helicopter”, Experiments in Fluids,(2021)

J. BARLOW, W. RAE, A. POPE, Low-Speed Wind Tunnel Testing, 3rd ed., John Wiley and Sons, (1999)